Change the networking selection to Stand alone (unless you have a license available), and then click Next. If we cannot reproduce the reported problem, we may ask you to send a copy of your project. This will isolate this Vijeo Citect on the network to allow it to run as a stand-alone system. Report program errors through the following channels: Multi-Processing is used to distribute server tasks across multiple CPUs. Go to our web site at then go to the HEC-RAS support page.I have been having a problem with Citect for a month now and we just can't find a reason for it nor a solution.We have bought a copy of Citect 7.20 and the complimentary license key(600 points if I am not mistaking). The SCADA software Citect hangs and crashes after about 15 hours of work since it has been started(I has always done this, it didn’t just start as if it has been working fine). The communication between the SCADA and the PLC is over the OPC server SimaticNET 2008 Edition. This video shows you how to solve issues related to CitectSCADAs Floating License Manager, including the Software Protection Failure. The SCADA was installed on a computer with Win7 Professional but since the problems occurred we thought that the OS is problematic. We changed it with a brand new PC with WinXP Professional, so the system dependent errors are kind of ruled out. We installed the SP2 and nothing was fixed. Plug the key you would like to update in a local USB port. The project uses one trend server and one alarm server. On the Activity Bar, select Licensing from the menu. On the Sentinel Key Update panel, click Launch. (See below for a description of the CiUSAFE dialog box fields.) Retrieve the Serial Number for the. No scripts added by me, except the ones to call a popup trend or the page change. License for a newer version is not yet included in the license file. just a plain display system with no writing(to the PLC) features yet. In Config Services tab in LM tools, the Path to the lmgrd.exe file is pointed at an older lmgrd.exe from previous version of LM Tools. 17514, time stamp: 0x4ce7b8f0įaulting application start time: 0x01ccb3036bfeb1b0įaulting application path: C:\Program Files\Schneider Electric\Vijeo Citect 7.20\Bin\Citect32.exeįaulting module path: C:\Windows\system32\KERNELBASE.dll Here is the error report in Windows Event Viewer:įaulting application name: Citect32.exe, version: 7.20.0.598, time stamp: 0x4ca34105įaulting module name: KERNELBASE.dll, version. I have attached one of the exception reports which Citect generated. Citect is designed to work in a networking environment. I would be grateful even on hints why would this happen, because Schneider Electric Bulgaria couldn't even give me those let alone a solution. CitectSCADA, CitectHMI/SCADA, CitectFacilities and CitectSCADA Batch are regisitered. However, for the example that will be described here, it will run on a single computer and communicate with a DVT 600 through Ethernet TCP/IP. compiler is finished, you can locate each compile error and display. Please check the server log file for errors. I wrote to Schneider Electric Global and I'm still waiting for a reply. #CITECT 6.1 LICENSE ERROR SERIAL NUMBER#.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |